
What UPS · Short Backup Covers
LiFePO₄ 2C high-rate short backup serves data centers and server rooms. Indoor telecom macro base stations get 4H+ backup with peak-shaving. Outdoor micro-stations get IP67 wide-temperature endurance. Industrial production lines get IP54 anti-vibration protection against dust, shock and voltage sags.
Life-support and medical equipment get IEC 60601 zero-switching-delay packs. Banks and surveillance get 99.999% availability on dual-redundant power. Edge computing nodes get 2U ultra-compact packs with predictive maintenance. Traffic and railway signaling get EN 50121-certified 2H+ backup.
Commercial buildings get cost-effective packs for lifts, POS and security. Home and SOHO get compact silent packs. PLB builds every one of them on self-developed 26650 LiFePO₄ cells, with in-house BMS design, cabinet-level integration and full certification — one supplier for the whole backup chain.
Ten UPS · Short Backup Sub-Scenarios
Each sub-scenario page covers the pain points that scenario faces, how PLB helps you solve them, a comparison table and the recommended models — so you can compare and choose faster.
Data Center & IDC UPS Batteries
Rack and cabinet backup for colocation, cloud and enterprise data halls — high-rate discharge, 19-inch form factors, RS485 / CAN monitoring and hot-swappable modules.
Telecom Macro Base Station UPS
Indoor macro sites needing 4-hour backup: 75% less weight, 95% site approval and peak-shaving that pays for itself in under six months.
Telecom & Edge Site UPS
Outdoor cabinets and 5G base stations: −20 °C to 60 °C operation, remote monitoring and front-access installation for narrow shelters and pole sites.
Industrial & Manufacturing UPS
Protection for PLC lines, robots and process control: wide temperature range, high cycle life under frequent outages and dry-contact alarms for the control room.
Medical Device UPS
Operating theatres, imaging and hospital IT: 0 ms switching, IEC 60601-1-2 medical EMC and SNMP integration with automatic safe shutdown.
Finance & Security UPS
Trading floors, vault surveillance and branch networks: 99.999% availability, 4–8 hour backup and one-click compliance reporting.
From Selection to After-Sales — PLB Stays With You
Four commitments that apply to every page in this category, from the first technical question to long-term support.

Technical Selection Support
Engineer recommends within 24 hours
Tell us the load profile, backup time and installation space — our engineers size the pack and recommend the matching model within 24 hours.
Dedicated technical team · 24-hour response
OEM / ODM Customization
From cell to cabinet, fully customizable
From cells, BMS, housing and terminals to the nameplate, everything can be customized.
4–8 week customization · Tooling development supported
Global Shipping
Export to 100+ countries
Export-compliant packaging with UN 38.3 air transport certification and worldwide delivery.
UN 38.3 certified · MSDS available · Export compliant
Warranty & Support
Standard warranty, lifetime support
Standard products carry a full warranty, backed by lifetime technical support.
Warranty terms on request · Lifetime technical supportWhy Choose PLB?
Years of Manufacturing
Founded in Dongguan, China in 2014
Countries Served
Export-compliant packaging and worldwide delivery
Voltage Platforms
From 25.6V to 512V, built on the same cell platform
After-Sales Rate
Monitored by the internal quality traceability system
Full Range & Model Selection
Complete product range and model selection — rack modules for data halls, cabinet packs for industrial rooms and outdoor packs for telecom sites.
| Model | Voltage | Capacity | Continuous current | Form factor | Applications |
|---|---|---|---|---|---|
| 25.6V 50Ah | 25.6V | 50Ah | 50A | Module | Small control rooms · edge cabinets |
| 25.6V 100Ah | 25.6V | 100Ah | 100A | Module / rack | Industrial UPS · small data rooms |
| 48V 100Ah | 48V | 100Ah | 100A | 19-inch 3U | Telecom sites · edge data centers |
| 51.2V 200Ah | 51.2V | 200Ah | 200A | 19-inch rack | Data center UPS · colocation |
| 512V 100Ah | 512V | 100Ah | 500A | Cabinet | Large UPS rooms · 1–800kVA systems |
By system size: up to 10kVA → 25.6V modules.
By environment: Data hall → 19-inch rack modules.
Not sure? Send us the load profile and required backup time — our engineers will size the system directly.
Frequently Asked Questions
The questions UPS buyers and facilities engineers ask most about LiFePO₄ UPS modules in the UPS · Short Backup scenario — 1–800kVA (system coverage) and 500A (continuous discharge), and what it takes to qualify.
Which pack fits the UPS · Short Backup cabinet already in service?
Modules are sized to common lead-acid blocks and cabinet voltages (25.6 V, 48 V, 51.2 V, 512 V) with the same terminal layout and 19-inch or cabinet mounting, so the string, breaker and charger settings carry over. For UPS · Short Backup builds the range starts at 51.2V 100Ah and 51.2V 200Ah, specified at 1–800kVA (system coverage).
How much usable capacity does the pack deliver across a backup window in UPS · Short Backup service?
At equal nominal capacity the LiFePO₄ pack delivers roughly 90% usable energy against about 60% for lead-acid, and 2C high-rate discharge covers the short backup window without derating. Key figure: 500A (continuous discharge).
Will the pack survive UPS · Short Backup conditions for its full service life?
The standard series is rated −10 °C to 50 °C and the low-temperature D-series −20 °C to 60 °C, with BMS thermal protection in both. Endurance: 2,000+ (deep cycles).
How does the pack connect to the charger and control system in the UPS · Short Backup scenario?
RS485, CAN and dry-contact alarms report cell voltage, current, temperature, SOC and alarms to the UPS or site monitoring system.
Can the pack be customized for the UPS · Short Backup application and certification file?
Cells, BMS, housing, terminals and nameplate are customizable. Custom packs take 4–8 weeks including tooling. Tell us the load profile, backup time and installation space — our engineers size the pack and recommend the matching model within 24 hours.
Need a Selection Recommendation?
Tell us the load, backup time and installation space — our engineers will recommend the matching battery within 24 hours.
NDA available upon request · Typical response within 12 hours



